follows to let you know how to run with the rolling sublimation hd transfer machine and check different problem with the machine.one : steps to you run with the rolling sublimation hd transfer machine..
1 Open air switch , the main power button is pressed , the red indior light , turn the hting switch , temperature controller green light , the unit starts hting .
2 temperature settings .
( 1 ) The bottom temperature controller DIP Digital dial at 250 ° C, a small green light to start automatic temperature control .
( 2 ) When the temperature is displayed about 250 ° C is rched, the red light indies the temperature has to work to transfer .
( 3 ) If the transfer , the temperature is too low , set the temperature to incrse more appropriate , whers lowered more.
( 4 ) must be checked before ch start over dial settings, to prevent people from setting too high and blankets.
( 5 ) Open the motor switch , which was appropriated forward on the governor from left to right slowly turn the knob to the proper speed can be.
3 How to transfer .
put the printed sublimation paper to the blanket , so it will be out all to the cloth or fabric ..
4 power handling .
In order to ensure the transfer finished , turn off the motor after the belt drive , this time can still transfer , the same effect ( note the speed to be consistent ) .
5 To ensure the transfer blanket life, plse After ch transfer , the dial is tuned to 95 ° C or less , the machine continues to rotate until the temperature drops below 100 ° C , you can stop.
two: analyze rolling sublimation hd transfer machine different problems!
1 meter did not show after boot .
Solution: Check the power contacts are good
2 showing the motor , but it does not work.
Solution: check the power indior light does not light :
( 1 ) may be exposed to bad .
( 2 ) the relay is good
3 high temperature table adjusting temperature , but the transfer is light in color ...
( 1 ) Check the relay switch .
( 2 ) hting the terminal ends of the tube in contact with power lines or bad connection in the hting roller is not good contact between the tube sheet .
( 3 ) may transfer temperature is not enough
( 4 ) blanket deviate .
( 5 ) according to the instructions carefully adjusted , to observe
( 6 ) hting time is very long, but still negative light in color
Solution: hting pipe is bad or aging
Solution: Check the voltage rches 220V
( 7 ) Check the motor reversing relay can not be adjusted or the base is bad or if the motor is not damaged motor speed control switch is bad check volatility
No comments: